Sanitary Vacuum Sensor with Display

The flush pressure sensors of the PI27/PI28 series with full stainless steel housing are designed for use in process technology. They are resistant to high-pressure cleaning with aggressive cleaning agents. Their high protection rating IP 69K, a hygienic design and a high temperature resistance qualify the sensors for use in the food and pharmaceutical industries.

  • High overall accuracy and electronic temperature compensation
  • Programmable analog and switching output
  • Hygienic, flush design
  • Aseptoflex Vario – G 1 process connection with four sealing options
  • High temperature resistance

Description

Ceramic capacitive

The most important element of the ceramic capacitive technology is the ceramic (Al2O3) measuring cell. After assembly, the ceramic cell element resembles a plate capacitor with a reference electrode and a measuring electrode placed 0.01 mm apart. The capacitance is inversely proportional to the distance between the electrodes. As pressure is applied, the distance changes by a small value and the capacitance changes proportionately. This signal is then converted into pressure by a microprocessor.

  • Robust direct sensing measurement technology
  • Eliminates possibility of contamination from diaphragm fill fluid
  • Long-term stability of ceramic cell design does not fatigue like stainless steel
  • Internal support construction creates very high pressure ratings
  • Ceramic cell is more resistant to abrasion, dents or dings that can create measurement offsets
  • Highest overload pressure rating, especially with dynamic pressure peaks