PT Temperature Pilot With Copper Bulb and Thermowell

PT Temperature Pilot With Copper Bulb and Union connection allowing it to be screwed into the side of a tank or pipe. The sensing bulb is in direct contact with the process fluid. Sensing bulb can be removed by unscrewing union nut (union hub remains in place).

The PT-Temperature Pilots are used with the HD regulator to control temperature in various processes and systems. Some examples are: oil heaters, ovens, process heaters, vats, dryers and jacketed kettles. Thermostatic sensing bulb comes with standard 8-ft. or 15-ft. capillary lengths. Temperature adjustment is accomplished by rotating an adjustment knob to the desired temperature setting.

The HD Regulator can be used with both the PP-Pressure Pilot and PT-Temperature Pilot simultaneously to limit pressure and control temperature in process applications.

  • Temperature adjustment made simple and easy by rotating an adjustment knob to the desired temperature setting
  • Thermostatic sensing bulb comes with an 8-ft. or 15-ft. length capillary
  • Capillary is armor-protected to resist damage
  • Overheat protection bellows is incorporated into sensing bulb; 200°F overheat protection up to 350°F
  • Full port strainer and blowdown valve on pilot adapter for protection of pilot from dirt and scale

Catalog Specification Sheet

I&M

I&M Quick Install

ModelTemperature RangeCapillary Length
PTUBW-31-8200°F - 260°F8 Ft
PTUBW-32-8240°F - 300°F8 Ft
PTUBW-14-8100°F - 160°F8 Ft
PTUBW-29-8120°F - 180°F8 Ft
PTUBW-12-860°F - 120°F8 Ft
PTUBW-30-8160°F - 220°F8 Ft
PTUBW-12-1560°F - 120°F15 Ft
PTUBW-30-15160°F - 220°F15 Ft
PTUBW-14-15100°F - 160°F15 Ft
PTUBW-29-15120°F - 180°F15 Ft
PTUBW-31-15200°F - 260°F15 Ft
PTUBW-32-15240°F - 300°F15 Ft

Description

PT Temperature Pilot With Copper Bulb and Thermowell’s brass well isolation well isolates the copper sensing bulb from the process fluid. Sensing bulb can be removed by unscrewing union nut.

Union Hub & Isolation Well remain in place which allows the removal of the sensing bulb without having to drain the tank.

Controlling Temperature
PT-pilot is used for temperature control when steam is used on heating applications. The PT style pilot is a “solid liquid fill” design. It’s made up of a temperature probe connected by a length of capillary tubing to a bellows in the pilot valve.

When the temperature bulb is heated the liquid inside the probe expands the bellows and closes off the pilot valve. The opening and closing of the pilot controls the flow of steam thru the main valve; which maintains system temperature. PT-pilot controls temperature through a range of 60-300°F. An overheat protection bellows is incorporated into sensing bulb.

Application Data Sheet – Fill Out and Return for Accurate Quote