Cryogenic Quench Relief Control Valves

SERVICE RANGE:

  • Temperature: -457.6 to 176ºF (-272 to 80ºC)

VALVE FUNCTION:

  • Protect the superfluid helium enclosures of superconducting magnets against over-pressure resulting from resistive transitions (Quench) as well as some of the cryogenic lines (QRL).

DESIGN FEATURES:

  • Superfluid helium service (Temperature: 1.9 K)
  • Set pressure : 17 bar (full open pressure : 20 bar)
  • Angle body
  • Cold box adaptation
  • Single or double bellows sealed
  • Remote control actuation (on/off function)
  • Flow coefficient : Kv 30
  • No risk of icing or jamming when operating
  • Downstream pressure does not affect the set pressure
  • Very low heat inleak
  • Resistant to radiation
  • Typical fluid : liquid He, liquid Ox, liquid H2, liquid N2

Description

Size Range(s)

  • NPS 1-1/2
  • (DN 40)

Pressure Rating

  • ASME Class 300

Standard Connections

  • Butt Weld

Downloads: