Description
Construction
A diaphragm made of 1.4435 stainless steel forms a flush separation of the process medium from the pressure transmitter.
The process pressure is transmitted hydrostatically from the diaphragm, via an FDA-approved system fill fluid, to a piezoresistive sensor.
The measuring range covers 0 … 250 mbar up to 0 … 25 bar.
The model SA-11 pressure transmitter is powered with a DC voltage of 10 (14) … 30 V. As output signals, 4 … 20 mA, 0 … 20 mA or 0 … 10 V are available.
A stainless steel case, with an ingress protection of up to IP68, offers a secure protection for external cleaning with splash water and enables its use in high-humidity environments. Through the integrated cooling element, process temperatures of up to 150 °C [302 °F] can be realised.