612.20 Copper Alloy Capsule Pressure Gauge

Applications

  • Low pressure pneumatic systems
  • Suitable for fluid medium, gaseous or dry that does not corrode copper alloy.

Product features

  • Low pressure series
  • Copper alloy wetted parts & stainless steel case
  • Capsule pressure gauge

Downloads

Application Datasheet – Fill Out and Return for Most Accurate Quote

Description

Design

  • EN837-3

Size

  • 2.5″
  • 4″
  • 6″

Accuracy class

  • ± 1.5% of span

Ranges (All ranges not stocked)

  • Size 2.5″: (63 mm): 0…10 (25 mbar) to 0…250″ H2O (600 mbar)
  • Size 4″ (100 mm): 0…4″ H2O (10 mbar) to 0…250″ H2O (600 mbar)
  • Size 6″ (160 mm): 0…2.5″ H2O (600 mbar) or all other equivalent vacuum or compound ranges

Connection

  • Copper alloy
  • Size 2½ (63 mm): ¼” NPT lower moutn (LM) or center back moutn (CBM)
  • Size 4″ & 6″ (100 mm & 160 mm): ¼” NPT or ½” NPT lower mount (LM) or lower back mount (LBM)

Capsule Element

  • Material: copper alloy

Movement

  • Copper alloy, nickel-silver pinion gear and shaft. Zero adjustment screw on dial

Dial

  • White aluminum with black lettering

Pointer

  • Black aluminum (zero adjust on dial. Must remove window to access)

Case

  • 304 stainless steel with stainless steel bayonet ring

Weather Protection

  • Weather resistant (NEMA 3 / IP 54)

Standard Scales

  • in. H2O/mm H2O
  • oz.-sq. in./mm H2O
  • oz.-sq. in./in. H2O
  • PSI

Window Gasket

  • Buna-N

Window

  • Flat instrument glass

Working Range

  • Steady: Full scale value
  • Fluctuating: 0.9 x full scale value

Operating Temperature

  • Ambient: -4°F to 140°F (-20°C to 60°C)
  • Media: max. 212°F (+100°C) max. 176°F (+80°C) for 4” & 6″ LBM

Temperature error

  • Additional error when temperature changes from reference temperature of 68°F (20°C) +0.6% of span for every 18°F (10°C) rising or falling.